Boiler pressure keeps dropping? Three checks you can do yourself

A boiler pressure gauge with the needle in the green

Water where it shouldn’t be? Shut off the stopcock and call. A dispatcher talks you through it while a van heads out.

A healthy boiler sits between 1 and 1.5 bar when cold. If the needle keeps sliding below 1, the system is losing water somewhere. Three places account for most of it.

The radiator valves

Run a dry tissue around each valve and joint. A green or white crust is a slow leak that evaporates before it drips. One weeping valve is enough to lose half a bar in a week.

The pressure relief pipe

Outside, behind the boiler, a small copper pipe pokes through the wall. If it drips, the relief valve is letting water go and needs replacing.

The filling loop

Top the pressure up to 1.2 bar, close both valves fully and note the reading. If it climbs on its own, the loop is passing. If it falls within a day with no visible leak, the expansion vessel has probably lost its charge. Either one is a single visit for a heating engineer.